By clicking “Accept”, you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts. View our Privacy Policy for more information.

Rover Features

equipment
features

Heads and Tusks

features

Counterpoise Arm

features

Ergoknobs

Components

The Rover is designed to perform radiographic X-ray examinations for disease/injury detection, diagnosis, medical and surgical treatment planning, and therapy monitoring, where patient condition prohibits transport to a fixed X-ray unit. The Rover can be used on pediatric and adult patients, in all patient treatment areas.

features

Dose Area Product (DAP)

Pediatric Filters

Traditional Thermionic Tube Vs Nano Electronic X-Ray (NEX Technology™)

Old

features

Heated tungsten filament cathode emits streams of electrodes which accelerate info the anode.
The impact on the anode generates massive heat and x-rays.

The heat generated adds complexity:
• Needs cooling - a rotating anode, oil bath, lead casing
adding weight
• Need ramp-up time to switch
x-rays on and off

features

New

features

Cold cathode carbon nanotubes emit
a precisely controlled electron stream
to anode.
The impact on the anode, produces x-rays.

Low heat enables simplification of tube, improving efficiencies:
• No rotating anode or oil bath
• Light weight due to reduction in size

X-rays can be switched on and off instantaneously with no ramping up time.

features

The Next Generation of Imaging Solutions 

NANO ELECTRONIC X-RAY TUBE (NEX) 

Medlink Imaging is proud to partner with Micro-X to introduce the first ROVER to be paired with VIVIX Detectors.

Micro-X is the first company in the world to introduce NEX Technology into medical imaging systems. NEX Technology is a simple, non-glass based x-ray tube, with no moving parts that generate minimal heat with no oil required for cooling. It uses carbon nanotubes to offer full medical imaging performance, in a smaller, lighter and more reliable x-ray tube.

features

Reliable 

No MotorsSimple Lightweight Moving PartsLess Chance of Breakdowns
Low Total Cost of Ownership
Long Battery Life

Efficient 

Fast Recharge
Green Choice
Small Footprint

Easy 

Easy To Maneuver
Fast to Accurately Position
Light to Transport and Easy to Control
Fast to Disinfect
Versatile Clinical Use

VXvue Acquisition Software

Digital Radiography Acquisitionfor VIVIX-S Series

software

Exclusive Radiography Acquisition

VXvue is a modern image acquisition program with specialized modules to acquire, adjust, and manage diagnostic images created by the VIVIX-S Series.

Advanced Image Processing | PureImpact™

PureImpact™ is a post-processing algorithm to enhance image quality for an efficient diagnosis.

Better Usability

Powerful Functions
Patient Multitask Management
Multilingual Software

Touch Interface for Tablet /Touch Screen Monitors

Touch-oriented Skin (Theme)
Touch-specialized Functions
Virtual Keyboard

Easy Customization

3 Types of Image Processing
Customizable Themes & Skins
Auto Rotation for
a Vertical Monitor

Optimized for Various Applications

Human
Vehicle
Veterinary
Equine

QXLink 3.3

The Vieworks Mini PACS

QXLink 3.3 is a mini PACS that allows users to access diagnostic images stored on the server.

DICOM 3.0 Compatibility
VXvue (Vieworks' viewer) Compatibility

Sample User Interface

Exclusive Radiography Acquisition

VXvue is a modern image acquisition program with specialized modules to acquire, adjust, and manage diagnostic images created by the VIVIX-S Series.

featuresfeatures

Wireless Portable Flat Panel Detector For Digital Radiography

Stable and Reliable AED

Easy Installation

High Image Quality

Fast Boosting Time

Efficient Workflow

panels

Convenient Charging

17”*17” fixed cassette size tethered panel

Stable and reliable AED (Automatic Exposure Detection)

VXvue Acquisition Software

Digital Radiography Acquisitionfor VIVIX-S Series

software

Exclusive Radiography Acquisition

VXvue is a modern image acquisition program with specialized modules to acquire, adjust, and manage diagnostic images created by the VIVIX-S Series.

Advanced Image Processing | PureImpact™

PureImpact™ is a post-processing algorithm to enhance image quality for an efficient diagnosis.

Better Usability

Powerful Functions
Patient Multitask Management
Multilingual Software

Touch Interface for Tablet /Touch Screen Monitors

Touch-oriented Skin (Theme)
Touch-specialized Functions
Virtual Keyboard

Easy Customization

3 Types of Image Processing
Customizable Themes & Skins
Auto Rotation for
a Vertical Monitor

Optimized for Various Applications

Human
Vehicle
Veterinary
Equine

VIVIX VW Series Wireless Panel & Medlink Workstation

workstationAdditional 1717V Spec Information
Dimensions

x18.5"x1.375'(WxLxD)

Weight

24.2 (lbs)  11(kg)

Scintillator

Gadox(GOS)

Pixels

3072*3072

Pixel Pitch

140μm

A/D Conversion

14 bit

Grayscale

16 bit

High-Res Image Display

3 Seconds

Workstation

Dell Workstation

Monitor

24" Touchscreen Monitor

The Medlink Rover Solution

*Specifications are subject to change without prior notice.

Specifications

Physical Characteristics
Height

1300 mm (51.2 in), head in docked/transport position, exc. cable

Width

Wheel base   583 mm (22.9 in)
Main chassis   500 mm (19.7 in)

Length

1371 mm (53.9 in), head in docked/transport position

Weight

Rover   95-105 kgs (209 lbs)
Rover Plus   Approx. 112 kgs

Drive handle height

System, Panel & Workstation   5 years
X-ray Tube   5 Years (prorated)
Collimator   1 Year

Technical output

Rover   max. 110kV@12.5mAs or 70kV@20mAs
Rover Plus   max. 120kV@50mAs or 70kV@80mAs

Operating specifications

Temperature Range   +10˚C to +30˚C Relative
Humidity Range   30% to 60%Atmospheric pressure

Drive Characteristics
Drive Type

Manual

Speed

Walking Speed

Brakes

Dead Man Braking controlled through buttons located on the drive controls

Speed

System, Panel & Workstation   5 years
X-ray Tube   5 Years (prorated)
Collimator   1 Year

Maximum incline

5 degrees (head in docked/transport position)

Electrical/Charge Capacity
Number of batteries

5

Type

LiFePO4 also called LFP for Lithium Ferro-Phosphate

Nominal voltage

14.4 Vdc each, total battery bank of 72 Vdc

Number of batteries

System, Panel & Workstation   5 years
X-ray Tube   5 Years (prorated)
Collimator   1 Year

Capacity

7.5 Ah each

Charge power requirements

100 to 240 Vac, 50/60 Hz, 11 A to 5.5 A (110 W max.)

Battery LED

Light indicator displays battery charge level

Number of batteries

System, Panel & Workstation   5 years
X-ray Tube   5 Years (prorated)
Collimator   1 Year

Detectors | Vieworks VIVIX-S VAW/FAW Series
Panel

3643VAW

4343VAW

3643FAW

4343FAW

Scintillator

Csi: Ti (Cesium)

Csi: Ti (Cesium)

Flexible Csl

Flexible Csl

Field of View

17” x 17”
(43cm x 43 cm)

14” x 17”
(36cm x 43 cm)

14” x 17”
(36cm x 43 cm)

17” x 17”
(43cm x 43 cm)

Pixel Array

2560 x 3072

3072 x 3072

3548 x 4316

4316 x 4316

Pixel Size

139 micron

139 micron

99um

99um

A/D Conversion

16 bit

16 bit

16 bit

16 bit

kVp Range

40-150

40-150

40-150

40-150

Dimensions

15.1” x 18.1” x 0.6”

18.1” x 18.1” x 0.6”

38.4 cm x 46.0 cm x 1.5 cm

38.4 cm x 46.0 cm x 1.5 cm

Weight
(without battery)

2.8kg (6.18lbs)

3.3kg (7.28lbs)

2.4 kg (1 battery) 2.6 kg (2 batteries)

2.95 kg (1 battery) 3.15 kg (2 batteries)

Data interface

WiFi 802.11n/ac (5GHz)

WiFi 802.11n/ac (5GHz)

Gigabit Ethernet (wired) IEEE802.11n/ac (wireless)

Gigabit Ethernet (wired) IEEE802.11n/ac (wireless)

Battery (two incl.) Lithium Polymer

1600 images
for 8 hours

1600 images
for 8 hours

Lithium Ion 3,400mAh x 2
16 h (standby)
*3,000 images at a 15-second cycle

Lithium Ion 3,400mAh x 2 • 16 h (standby)
*3,000 images at a 15-second cycle

Also available with 25cm x 30cm panel size.

Specifications

Panel
3643VAW
3643VAW
3643VAW
3643VAW
Panel

4343VAW

3643VAW

3643FAW

4343FAW

Scintillator

Csi: Ti (Cesium)

Csi: Ti (Cesium)

Flexible Csl

Flexible Csl

Field of View

14” x 17”
(36cm x 43 cm)

14” x 17”
(36cm x 43 cm)

14” x 17”
(36cm x 43 cm)

17” x 17”
(43cm x 43 cm)

Pixel Array

3072 x 3072

2560 x 3072

3548 x 4316

4316 x 4316

Pixel Size

139 micron

139 micron

99um

99um

A/D Conversion

16 bit

16 bit

16 bit

16 bit

kVp Range

40-150

40-150

40-150

40-150

Dimensions

18.1” x 18.1” x 0.6”

15.1” x 18.1” x 0.6”

38.4 cm x 46.0 cm x 1.5 cm

38.4 cm x 46.0 cm x 1.5 cm

Weight
(without battery)

3.3kg (7.28lbs)

2.8kg (6.18lbs)

2.4 kg (1 battery) 2.6 kg (2 batteries)

2.95 kg (1 battery) 3.15 kg (2 batteries)

Weight
(without battery)

3.3kg (7.28lbs)

2.8kg (6.18lbs)

2.4 kg (1 battery) 2.6 kg (2 batteries)

2.95 kg (1 battery) 3.15 kg (2 batteries)

Data interface

WiFi 802.11n/ac (5GHz)

WiFi 802.11n/ac (5GHz)

Gigabit Ethernet (wired) IEEE802.11n/ac (wireless)

Gigabit Ethernet (wired) IEEE802.11n/ac (wireless)

Battery (two incl.) Lithium Polymer

1600 images
for 8 hours

1600 images
for 8 hours

Lithium Ion 3,400mAh x 2
16 h (standby)
*3,000 images at a 15-second cycle

Lithium Ion 3,400mAh x 2 • 16 h (standby)
*3,000 images at a 15-second cycle

Also available with 25cm x 30cm panel size.

Specifications

Physical Characteristics
Height

1300 mm (51.2 in), head in docked/transport position, exc. cable

Width

Wheel base   583 mm (22.9 in)
Main chassis   500 mm (19.7 in)

Length

1371 mm (53.9 in), head in docked/transport position

Weight

Rover   95-105 kgs (209 lbs)
Rover Plus   Approx. 112 kgs

Drive handle height

System, Panel & Workstation   5 years
X-ray Tube   5 Years (prorated)
Collimator   1 Year

Technical output

Rover   max. 110kV@12.5mAs or 70kV@20mAs
Rover Plus   max. 120kV@50mAs or 70kV@80mAs

Operating specifications

Temperature Range   +10˚C to +30˚C Relative
Humidity Range   30% to 60%Atmospheric pressure

Drive Characteristics
Drive Type

Manual

Speed

Walking Speed

Brakes

Dead Man Braking controlled through buttons located on the drive controls

Speed

System, Panel & Workstation   5 years
X-ray Tube   5 Years (prorated)
Collimator   1 Year

Maximum incline

5 degrees (head in docked/transport position)

Electrical/Charge Capacity
Number of batteries

5

Type

LiFePO4 also called LFP for Lithium Ferro-Phosphate

Nominal voltage

14.4 Vdc each, total battery bank of 72 Vdc

Number of batteries

System, Panel & Workstation   5 years
X-ray Tube   5 Years (prorated)
Collimator   1 Year

Capacity

7.5 Ah each

Charge power requirements

100 to 240 Vac, 50/60 Hz, 11 A to 5.5 A (110 W max.)

Battery LED

Light indicator displays battery charge level

Number of batteries

System, Panel & Workstation   5 years
X-ray Tube   5 Years (prorated)
Collimator   1 Year

Detectors | Vieworks VIVIX-S VAW/FAW Series
Panel

4343VAW

3643VAW

3643FAW

4343FAW

Scintillator

Csi: Ti (Cesium)

Csi: Ti (Cesium)

Flexible Csl

Flexible Csl

Field of View

14” x 17”
(36cm x 43 cm)

14” x 17”
(36cm x 43 cm)

14” x 17”
(36cm x 43 cm)

17” x 17”
(43cm x 43 cm)

Pixel Array

3072 x 3072

2560 x 3072

3548 x 4316

4316 x 4316

Pixel Size

139 micron

139 micron

99um

99um

A/D Conversion

16 bit

16 bit

16 bit

16 bit

kVp Range

40-150

40-150

40-150

40-150

Dimensions

18.1” x 18.1” x 0.6”

15.1” x 18.1” x 0.6”

38.4 cm x 46.0 cm x 1.5 cm

38.4 cm x 46.0 cm x 1.5 cm

Weight
(without battery)

3.3kg (7.28lbs)

2.8kg (6.18lbs)

2.4 kg (1 battery) 2.6 kg (2 batteries)

2.95 kg (1 battery) 3.15 kg (2 batteries)

Weight
(without battery)

3.3kg (7.28lbs)

2.8kg (6.18lbs)

2.4 kg (1 battery) 2.6 kg (2 batteries)

2.95 kg (1 battery) 3.15 kg (2 batteries)

Data interface

WiFi 802.11n/ac (5GHz)

WiFi 802.11n/ac (5GHz)

Gigabit Ethernet (wired) IEEE802.11n/ac (wireless)

Gigabit Ethernet (wired) IEEE802.11n/ac (wireless)

Battery (two incl.) Lithium Polymer

1600 images
for 8 hours

1600 images
for 8 hours

Lithium Ion 3,400mAh x 2
16 h (standby)
*3,000 images at a 15-second cycle

Lithium Ion 3,400mAh x 2 • 16 h (standby)
*3,000 images at a 15-second cycle

Also available with 25cm x 30cm panel size.